Marine Science Faculty Publications
Calibration of Membrane Inlet Mass Spectrometric Measurements of Dissolved Gases: Differences in the Responses of Polymer and Nano-composite Membranes to Variations in Ionic Strength
Document Type
Article
Publication Date
2013
Keywords
Membrane introduction mass spectrometry, Nano-composite membranes, Polydimethylsiloxane, MIMS calibrations, Salting-out coefficients, Pervaporation
Digital Object Identifier (DOI)
https://doi.org/10.1016/j.talanta.2013.05.014
Abstract
This work examines the transmission behavior of aqueous dissolved methane, nitrogen, argon and carbon dioxide through two types of membranes: a polysiloxane nano-composite (PNC) membrane and a conventional polydimethylsiloxane (PDMS) membrane. Transmission properties at 30 °C were examined by membrane introduction mass spectrometry (MIMS) at nearly constant gas partial pressures in NaCl solutions over a range of ionic strength (0–1 molal). Gas flow rates were examined as a function of dissolved gas concentrations using the Setschenow equation. Although MIMS measurements with PDMS and PNC membranes produced signal responses that were directly proportional to aqueous dissolved gas concentrations, the proportionalities varied with ionic strength and were distinctly different for the two types of membranes. With the exception of carbon dioxide, the PNC membrane had membrane salting coefficients quite similar to Setschenow coefficients reported for gases in aqueous solution. In contrast, the PDMS membrane had membrane salting coefficients that were generally smaller than the corresponding Setschenow gas coefficient for each gas. Differences between Setschenow coefficients and membrane salting coefficients lead to MIMS calibrations (gas-flow vs. gas-concentration proportionalities) that vary with ionic strength. Accordingly, gas-flow vs. gas-concentration relationships for MIMS measurements with PDMS membranes are significantly dependent on ionic strength. In contrast, for PNC membranes, flow vs. concentration relationships are independent (argon, methane, nitrogen) or weakly dependent (CO2) on ionic strength. Comparisons of gas Setschenow and membrane salting coefficients can be used to quantitatively describe the dependence of membrane gas-flow on gas-concentrations and ionic strength for both PDMS and PNC membranes.
Was this content written or created while at USF?
Yes
Citation / Publisher Attribution
Talanta, v. 116, p. 217-222
Scholar Commons Citation
Miranda, L. D.; Byrne, R. H.; Short, R. T.; and Bell, R. J., "Calibration of Membrane Inlet Mass Spectrometric Measurements of Dissolved Gases: Differences in the Responses of Polymer and Nano-composite Membranes to Variations in Ionic Strength" (2013). Marine Science Faculty Publications. 1770.
https://digitalcommons.usf.edu/msc_facpub/1770