Local characteristics of Postojna Cave climate, air temperature, and pressure monitoring
Files
Download Full Text
Publication Date
January 2011
Abstract
In Postojna Cave, air temperature and pressure monitoring has been conducted since July 21, 2008. Air pressure in the cave at three monitoring sites fluctuates synchronically with outside air pressure. Temperature data for Postojna 1 and 3 show good correlation with outside climate conditions for the period 2009–2010. The temperature at Postojna 1 was increasing constantly from March to May 2009, while at Postojna 2, it was decreasing. Postojna 1 has a seasonal trend in accordance with outer trend, while seasonal trend at Postojna 2 is just contrary to outside trend. Microclimate studies at Postojna 2 show local variability, especially in winter, and exhibit special microclimate conditions that may be due to ventilation of unknown passages in the back.
Keywords
Monitoring Site, Seasonal Trend, Diurnal Fluctuation, Cave System, Cave Entrance
Document Type
Article
Notes
Theoretical and Applied Climatology, Vol. 105, no. 3-4 (2011).
Identifier
SFS0071823_00001
Recommended Citation
Šebela, Stanka and Turk, Janez, "Local characteristics of Postojna Cave climate, air temperature, and pressure monitoring" (2011). KIP Articles. 3280.