Abstract

The Texas Water Development Board improved the calibration of the Edwards-Trinity (Plateau) and Pecos Valley Aquifers GAM by converting the model from a two-layer to a one-layer model and by adjusting many of the input parameters including the model boundaries, model base and top elevations, recharge, hydraulic conductivity, anisotropy, and storage. The updated model was also calibrated for a longer period of time, 1930 through 2005, than the original model which was calibrated for the period 1980 through 2000. The updated model was constructed and run using a newer version of MODFLOW: MODFLOW-2000 versus MODFLOW-96 in the original model. Additionally, calibration was achieved using parameter estimation software, PEST, along with FORTRAN pre-processors.

Keywords

Edwards-Trinity (Plateau), Pecos Valley Aquifers, Layer Groundwater Flow Model, Texas Water Development Board